DZ47LED-LNE Residual Current Circuit Breaker 10A~60A

Electrical Parameters Rated Current 10A, 15A, 20A, 25A, 30A, 40A, 50A, 60A Poles L+N+PE or L L PE Rated Voltage Ue AC 120V/240V Insulation Voltage Ui 500V Rated Breaking Capacity 6kA Over Voltage Protection Value 270V±5V Under Voltage Protection Value 90V±5V Rated Impulse Withstand Voltage (1.2/50) Uimp 4kV Dielectric Test...
Current
-
+
$14.00

DIHOOL

500 In Stock

Electrical Parameters

Rated Current 10A, 15A, 20A, 25A, 30A, 40A, 50A, 60A
Poles L+N+PE or L L PE
Rated Voltage Ue AC 120V/240V
Insulation Voltage Ui 500V
Rated Breaking Capacity 6kA
Over Voltage Protection Value 270V±5V
Under Voltage Protection Value 90V±5V
Rated Impulse Withstand Voltage (1.2/50) Uimp 4kV
Dielectric Test Voltage At And Ind. Freq. For 1min 2kV
Residual Current Working Type Type A
Residual Leakage Tripping Current 30mA/100mA/300mA
Thermo-Magnetic Release Characteristic C-Curve (5-10In)
Electrical Life 4000
Mechanical Life 10000
Installation 35MM Din Rail or M3 Screw Side Mount
Reference Temperature For Setting Of thermal Element 30℃
Ambient Temperature -5℃~+40℃
Terminal Connection Type Phillips Screws
Adapter Cable 6-63A 1.5-16mm² 16-5AWG
Tightening Torque 2.0N.M
Altitude 2000M
Surge Protection Parameters
Max Discharge Current In 8/20μs 10kA
Response Time <25ns
The ground terminal links the stranded copper conductors 6mm²
RCD Types
Type AC
General Purpose Use
RCD can detect and respond to AC sinusoidal wave only.
Type A
Equipment incorporating electronic components
RCD can detect and respond as for type AC,
Plus pulsating DC conponents.

Description Of Appearance

1. Before use, you need to press the Button, and then hand up , power on. (power indicator red, LED red light, green light)
2. If you do not press the  button before use, the will trip, automatically fall, the circuit cannot be connected.
3. The circuit is not connected, button can not work.
4. After connecting the circuit, press the button, open the upward, switch on the power, press the button, the circuit is disconnected, indicating that the leakage circuit is normal.

The Main Difference Between Type A And Type AC

Form Residual Current and Current Waveform that can trip Trip Current Range
Type AC AC Residual Current 0.5I△-I△n
Type A AC Residual Current 0.5I△-I△n
Pulsating DC Residual Current 0.35~1.4I△n (or 2I△n)(Current lag Angle 0°)
0.25~1.4I△n (or 2I△n)(Current lag Angle 90°)
0.11~1.4I△n (or 2I△n)(Current lag Angle 135°)
Current Stacking 6mA Pulsating Direct Current 1.4I△n (or 2I△n) + 6mA